HomeSitemap | Privacy Policy | Disclaimer |
 
 
 
 

 

KULKARNI BLOWERS/EXHAUSTERS PRODUCT LIST

Projected Test Bench Data

Back to Blower Products

 

Print

Static Blowers: KSR800
Blower speed
rpm
100 mbar 200 mbar 300 mbar 400 mbar 500 mbar 600 mbar 700 mbar 800 mbar 900 mbar 1000 mbar
Q KW Q KW Q KW Q KW Q KW Q KW Q KW Q KW Q KW Q KW
1550 8045 35 7884 55 7551 76 7438 100 7326 123 7235 147 7147 170 7060 180 6990 215 6927 240
1400 7267 32 7000 51 6733 69 6620 90 6509 111 5400 123 6330 154 6260 170 6180 190 6110 217
1300 6748 30 6600 48 6200 64 6080 84 5964 103 5870 119 5785 143 5720 158 5645 176 5565 202
1200 6142 28 6008 45 6544 59 5530 77 5419 95 5330 110 5241 132 5180 146 5112 165 5021 186
1100 5550 26 5430 42 5100 54 4987 70 4875 87 4795 101 4715 121 4660 134 4590 152 4500 172
1000         4555 49     4330 79     4152 110         3932 155

NB 300

DG Side BRG. NU 418 C-3
DN Side BRG. 7318 DB

These products are under development stage. The above data, therefore may undergo some changes.

Note :
  • All blowers are suitable for operation as Exhausters for depressions of up to 500 mbar
  • All the parameters are at 1013 mbar and 15o C
  • Temperature Information : Max. Inlet Temperature 50 deg. C. # Max. discharge temperature 170 deg. C.
  • Where non standard conditions strongly recommend you contact our technical staff who will be pleased to assist. Our computer systems are able to supply more detailed information, in the shortest possible time.
  • Above power ratings are for BKW, select motor rating 1.1 to 1.15 times BKW.

Back to Blower Products

 
 
Copyright © 2006-7 Kulkarni Power Tools Ltd.. All Rights Reserved.
Website designed by : Vertex Infoservices (P) Ltd.