KULKARNI
BLOWERS/EXHAUSTERS PRODUCT LIST
| |
|
Static Blowers:
SR010 |
Print
|
|
|
Speed RPM |
100
Q/KW |
200
Q/KW |
300
Q/KW |
400
Q/KW |
500
Q/KW |
600
Q/KW |
700
Q/KW |
760
Q/KW |
|
1000
DeIT. deg C |
-/- |
33/0.5
37 |
25/0.8
64 |
18/1.2
100 |
16/1.6
132 |
|
|
|
1500
DeIT. deg C |
63/0.3
15 |
52/0.6
32 |
40/1
55 |
28/1.3
86 |
23 |
0.9 |
2 |
1.2 |
2000
DeIT. deg C |
119 |
0.5 |
95 |
1 |
74 |
1.4 |
52 |
1.8 |
|
2500
DeIT. deg C |
169 |
0.7 |
146 |
1.3 |
124 |
1.9 |
103 |
2.5 |
|
3000
DeIT. deg C |
219 |
0.9 |
196 |
1.7 |
175 |
2.4 |
154 |
3.1 |
|
3500
DeIT. deg C |
269 |
1.2 |
247 |
2 |
226 |
2.9 |
204 |
3.8 |
|
4000
DeIT. deg C |
319 |
1.4 |
297 |
2.4 |
276 |
3.4 |
255 |
4.4 |
|
|
|
Note :
- All blowers are suitable
for operation as Exhausters for depressions of up
to 500 mbar
- All the parameters are
at 1013 mbar and 15o C
- Temperature Information
: Max. Inlet Temperature 50 deg. C. # Max.
discharge temperature 170 deg. C.
- Where non standard
conditions strongly recommend you contact our
technical staff who will be pleased to assist. Our
computer systems are able to supply more detailed
information, in the shortest possible time.
- Above power ratings are
for BKW, select motor rating 1.1 to 1.15 times
BKW.
|
|
|